Two-site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid  (2018)

Authors:
Buoro, S; Peruzzi, B; Fanelli, A; Seghezzi, M; Manenti, B; Lorubbio, M; Biagioli, T; Nannini, S; Ottomano, C; Lippi, Giuseppe
Title:
Two-site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid
Year:
2018
Type of item:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Language:
Inglese
Format:
A Stampa
Referee:
Name of journal:
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY
ISSN of journal:
1751-5521
N° Volume:
40
Number or Folder:
1
Page numbers:
26-33
Keyword:
XN; Sysmex; automated cell count; body fluid; cerebrospinal fluid
Short description of contents:
INTRODUCTION: Cellular analysis in cerebrospinal fluid (CSF) provides important diagnostic information in many pathological settings. The aim of this two-site study was to evaluate the Sysmex XN Body Fluid mode (XN-BF) for cell analysis of CSF compared to light microscopy (LM). METHODS: Two hundred and seven consecutive CSF samples were analyzed in parallel with XN-BF and LM. The study also included the estimation of the limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), carry-over and linearity of XN-BF module. RESULTS: LoQ of white blood cells (WBC) was 3×106 cells/L; linearity was good and carry-over negligible. XN-BF parameters were compared to LM for the following cell classes: total cells, WBC, polymorphonuclear (PMN), and mononuclear (MN) cells. The bias ranged from 1.3 to 15.2×106 cells/L. The receiver operating characteristics curve analysis for WBC showed an area under the curve of 0.98, and the global diagnostic agreement was 95% at a cutoff of 5×106 cells/L. CONCLUSIONS: XN-BF provides rapid and accurate counts in clinically relevant ranges of CSF values, thus providing a valuable alternative to conventional LM analysis. However, microscopic review remains advisable in samples with abnormal cell counts or high fluorescent (HF-BF) cell parameter exceeding 5×106 cells/L.
Web page:
https://doi.org/10.1111/ijlh.12723
Product ID:
100042
Handle IRIS:
11562/972132
Last Modified:
November 15, 2022
Bibliographic citation:
Buoro, S; Peruzzi, B; Fanelli, A; Seghezzi, M; Manenti, B; Lorubbio, M; Biagioli, T; Nannini, S; Ottomano, C; Lippi, Giuseppe, Two-site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid «INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY» , vol. 40 , n. 12018pp. 26-33

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<back

Activities

Research facilities

Share